Detections

Explore public detection logic contributed by the community across SIEM and rule languages.

233 detections

Detects command execution patterns on NetScaler appliances involving the extraction of system details (id, uname, hostname, nsrelease) and writing or echoing them into HTML files within NetScaler web directories, indicative of web shell installation or staging.
avatar
ills3c Intel&Coffee@Ills3C
avatar
Detections.ai Community
5 days ago
105
Detects successful administrative login events originating from IP addresses outside of configured trusted management networks on Fortinet devices.
avatar
Kjetil Fjas@Kjefjas
avatar
Detections.ai Community
8 days ago
4010
Correlates a CVE-2026-76504 encoded /%6a_security_check login POST with a follow-on /dataservice/admin/user request from the same client to the same vManage within 10 minutes. Summarized and sorted by follow-on count.
avatar
ills3c Intel&Coffee@Ills3C
avatar
Detections.ai Community
2 days ago
102
Detects CVE-2026-76504 Cisco SD-WAN vManage authentication bypass attempts: POST logins using internal viptela-reserved-* accounts via the percent-encoded /%6a_security_check path. Summarized per host and account.
avatar
ills3c Intel&Coffee@Ills3C
avatar
Detections.ai Community
2 days ago
001
Detects CVE-2026-76504 Cisco SD-WAN vManage authentication bypass attempts: POST logins using internal viptela-reserved-* accounts via the percent-encoded /%6a_security_check path. Summarized per host and account.
avatar
ills3c Intel&Coffee@Ills3C
avatar
Detections.ai Community
2 days ago
000
Correlates a CVE-2026-76504 encoded /%6a_security_check login POST with a follow-on /dataservice/admin/user request from the same client to the same vManage within 10 minutes. Summarized and sorted by follow-on count.
avatar
ills3c Intel&Coffee@Ills3C
avatar
Detections.ai Community
2 days ago
000
Detects external inbound FortiGate Fabric Management Protocol (FGFM) traffic on TCP port 541 followed by a FortiGateCloud administrative configuration download, backup, or running-config event on the same FortiGate device within a one-hour window, potentially indicating unauthorized configuration access or device compromise.
avatar
Arnold Chan@slaz
avatar
Detections.ai Community
12 days ago
006
Detects external inbound FortiGate Fabric Management Protocol (FGFM) traffic on TCP port 541 followed by a FortiGateCloud administrative configuration download, backup, or running-config event on the same FortiGate device within a one-hour window, potentially indicating unauthorized configuration access or device compromise.
avatar
Arnold Chan@slaz
avatar
Midnight Slayer
12 days ago
005
Detects external inbound FortiGate Fabric Management Protocol (FGFM) traffic on TCP port 541 followed by a FortiGateCloud administrative configuration download, backup, or running-config event on the same FortiGate device within a one-hour window, potentially indicating unauthorized configuration access or device compromise.
avatar
Arnold Chan@slaz
avatar
Hunters
12 days ago
005
Detects external inbound FortiGate Fabric Management Protocol (FGFM) traffic on TCP port 541 followed by a FortiGateCloud administrative configuration download, backup, or running-config event on the same FortiGate device within a one-hour window, potentially indicating unauthorized configuration access or device compromise.
avatar
Arnold Chan@slaz
Defender - KQL
12 days ago
104
This rule detects devices with a BIOS release date older than 730 days (2 years), which could indicate unpatched or outdated firmware posing security and stability risks.
avatar
Jan Mulder@Wolkenman
HuntingSpace
13 days ago
003
Detects external inbound FortiGate Fabric Management Protocol (FGFM) traffic on TCP port 541 followed by a FortiGateCloud administrative configuration download, backup, or running-config event on the same FortiGate device within a one-hour window, potentially indicating unauthorized configuration access or device compromise.
avatar
Arnold Chan@slaz
avatar
Detection & Hunting Community
12 days ago
002
Detects potential unauthorized or suspicious configuration changes related to packet sniffer objects and associated authentication or management ports on FortiGate firewalls across multiple devices.
avatar
Arnold Chan@slaz
avatar
Detections.ai Community
12 days ago
202
Detects post-exploitation activities associated with FortiMail vulnerability CVE-2026-104286 (FG-IR-26-175). The rule identifies potential unauthorized persistence and data exfiltration, including the creation or modification of archive accounts with remote destinations, execution of 'migadmin' via root cron, and specific admin logout anomalies.
avatar
Tim Peck@timpeck
avatar
Detections.ai Community
24 days ago
5057
Detects potential unauthorized or suspicious configuration changes related to packet sniffer objects and associated authentication or management ports on FortiGate firewalls across multiple devices.
avatar
Arnold Chan@slaz
avatar
Midnight Slayer
12 days ago
000
Detects potential unauthorized or suspicious configuration changes related to packet sniffer objects and associated authentication or management ports on FortiGate firewalls across multiple devices.
avatar
Arnold Chan@slaz
Defender - KQL
12 days ago
000
Detects potential unauthorized or suspicious configuration changes related to packet sniffer objects and associated authentication or management ports on FortiGate firewalls across multiple devices.
avatar
Arnold Chan@slaz
avatar
Hunters
12 days ago
000
Detects potential unauthorized or suspicious configuration changes related to packet sniffer objects and associated authentication or management ports on FortiGate firewalls across multiple devices.
avatar
Arnold Chan@slaz
avatar
Detection & Hunting Community
12 days ago
000
This rule monitors for Cisco ASA/FTD device logs indicating an unexpected process crash (e.g., 'crashinfo', 'Traceback', 'decode-CF process restart') in conjunction with logs related to WebVPN activity or malformed HTTP requests. This pattern is indicative of potential exploitation attempts against the Cisco WebVPN service, such as those targeting CVE-2026-20349.
avatar
Ankit Mehta@Secvyn
avatar
Detections.ai Community
30 days ago
0019
This rule detects anomalous outbound SMTP (port 25) traffic originating from a NetScaler ADC or Gateway appliance. Since these appliances have no legitimate business requirement to initiate outbound SMTP communication, such traffic is a strong indicator of post-compromise activity, potentially used for command and control or data exfiltration.
avatar
Ankit Mehta@Secvyn
avatar
Detections.ai Community
30 days ago
0010
This rule identifies MikroTik devices running vulnerable versions of RouterOS (specifically those older than 7.24) that are susceptible to CVE-2026-84411. This vulnerability involves an integer underflow in the web management HTTP handling, which can lead to unauthenticated remote code execution or denial of service.
avatar
Ankit Mehta@Secvyn
avatar
SlimKQL 2026
30 days ago
709
Page 1 of 12